The ASTAT BP soft starter delivers smooth, reliable performance for extended motor and component life for a range of standard AC motors from 8 Amps to 1100 Amps and from 208V to 600V. With an internal run-time bypass contactor, the SCRs in the ASTAT BP are automatically bypassed at the end of ramp, which results in less heat generated, smaller enclosures and reduced wiring.

The ASTAT BP Soft Starter has a simple interface for fast set-up and operation

Its backlit LCD screen has full descriptions of parameters which makes the ASTAT BP Soft Starter easy to use. In two rows of 16 characters each, it displays the function selected and the value of the setting and/or monitor. Selecting and changing parameters is simply done with the arrow keys. There also four user selectable languages (English, German, Italian, and Spanish), it delivers:
Data Readouts e.g. Line Voltage, Motor Current, etc.
Fault Diagnostics e.g. Overload, Overvoltage, Undercurrent
Statistical Data e.g. Elapsed Run Time, Fault Recording, Trip Event, etc.
Parameter Settings – e.g. Acceleration Time, Starting Voltage, Motor FLA
Features and Benefits

Current ratings: 8A-1100A: 8, 17, 31, 44, 58, 72, 85, 105, 145, 170, 210, 240, 310, 360, 414, 477, 515, 590, 720, 840, 960, 1100
Line Voltage:
3ph, 208-440V 50/60Hz. (Type QB1x, 1400V PIV ratings)
3ph, 460-600V 50/60Hz. (Type QB2x, 1600V PIV ratings)
Frequency Range: 45Hz-65Hz, auto-tracking frequency range
Control Voltage:110VAC, +10, -15%, 50/60Hz or 230VAC, +10, -15%, 50/60Hz
Motor Protection:NEMA Class 10, 20 and 30 overload and IEC Class 10 or 20
Internal Bypass: With the internal bypass there is no need for wiring in an external contactor and adding space to the installation
Pump Control: Avoids overpressure at the end of the acceleration phase and suppresses hammering at the stopping phase
Communication Networks: Modbus RTU is built in
LCD Display & Six-Button Keypad: Saves time by setting up the ASTAT BP using full parameter descriptions instead of codes
In-Line or Inside-Delta Operation: Choose either traditional Line or Inside Delta operation, which allows the ASTAT BP to easily replace Y/D starters and allows the unit’s rating to be reduced by as much as 1.5 times
Torque Control: Controlled torque ramps produce results close to linear speed without tachometer feedback
Generator Supply: Helps minimize the negative effects caused by the generator voltage fluctuations during starting

Applications

Pumps
Fans
Compressors
Conveyors
Except the brand above, we can also provide the other brands as follows:
Solcon Soft Starter
Benshaw Soft Starter
Emerson Soft Start
Toshiba Starter
Emotron Softstarter
Baldor Soft Starter
Omron Soft Starter
Allen-Bradley Soft Starter
Rockwell Soft Starter
Moeller soft starter
GE Soft Starter
OMRON Soft Starter
AuCom Soft Starter
Eaton Soft Starter
Motortronics Soft Starter
Cutler Hammer soft start
Motortronics soft starter
Franck Soft Starter
Delixi Soft Starter
SMC Soft Start
SCR Soft Start
Carlo Gavazzi Soft Starter
Festo Soft-start Valve
Siemens Soft Starter
Moeller Soft Starter
Telemecanique Soft Start
CNYH Soft Starter
Mitsubishi Soft Starter
Danfoss Soft Start
AELTA Soft Start
CHINT Soft Starter
CARLO GAVAZZI Soft Start
Solcom&hapn Soft Start
CNYH Soft Start
CHNT Soft Start
Altistart soft start
ATS soft starter
Sirius soft starter
Star Delta soft starter
Aucom soft starter
CHZIRI Soft Starter
People Electric Soft Starter
Hpan Soft Starter
Andeli Soft Starter
WEG Soft Starter
Schneider Soft Starter
ABB Softstarter
Should you have any questions, please feel free to ask us.

Tags:
Prev:
Next: