Thermal oil boiler online cleaning
AJ-8-021 high temperature heat conduction oil cleaning agent (on-line cleaning agent for heat conduction oil furnace) is used for online chemical cleaning of heat conduction oil furnace and its piping system during non-stop operation. The heat conduction oil system can be operated under 300 ℃ without shutting down It is directly added and used, which truly realizes the purpose of non-stop cleaning of the heat-conducting oil furnace. AJ-8-021 high temperature heat transfer oil cleaning agent (on-line cleaning agent for heat conduction oil furnace) dissolves various insoluble grease and carbon deposits in the system through a special chemical reaction. The cleaning nature is gentle, the operator is safe, and does not affect the normal operation of the system.
Characteristics of high temperature heat transfer oil cleaning agent:
Non-corrosive: After being added to the system to start cleaning, the characteristics of the system’s heat transfer oil will not be changed, and the cleaning process will be completed under non-corrosive conditions.
Thorough cleaning: It can thoroughly remove all kinds of insoluble grease and carbon deposits.
Cleaning safety: The cleaning process is to dissolve the grease and carbon deposits in the system, and the cleaning fluid and oil are integrated, and there is no dirt shedding during the whole cleaning process.
Easy to use: just add the thermal oil furnace online cleaning agent to the running system as required.
Safe and harmless: harmless to the human body and the natural environment, it runs directly in the normal operating system.
Low cost: The cost of medicine is much lower than the cost of traditional parking cleaning.
Application range:
Various boilers and piping systems using heat transfer oil as the medium.
Using method of high temperature heat transfer oil cleaning agent: (The following data is a reference number, please contact the company for the specific addition ratio)
Add 5%-15% of the oil capacity of the heat conduction oil furnace system according to the operating conditions of the system. The heat conduction oil system running below 300℃ can be directly added and used without stopping the system, and the system is filled with medicine. The cleaning is completed by itself in 5-7 days.
How to use
Before discharging the degraded heat transfer oil from the heat transfer oil heating system device, add 5%-15% of the volume of AJ-8-021 high temperature heat transfer oil cleaning agent into the system, and then continue to run 5- 7 days. During this period, closely check the system’s built-in filter device to prevent clogging with residue. Then drain the system completely and inject new oil.
If you have product needs and questions, please call Hebei Aijieneng Cleaning Service Co., Ltd. to obtain a cleaning plan and quotation.